ILT5000 Lab Radiometer for Broadband Germicidal and UV Hazard Measurements

Research Germicidal Light Measurement System

ILT5000, SED240/ACT5/W

Part Number: ILT5000,SED240/ACT5/W US
$4,339.00

Research Germicidal Light (UV disinfection) & Optical Radiation Hazard Measurement System

  • 10+ Decade Dynamic Range of Optical Analysis
  • Pico-ammeter: 10fA to 1mA (calibrated from 100fA - 1mA)
  • Wireless Communication, Built-in
  • User controlled or Auto: Range, Zero/Dark, Sample Rate
  • 4-20 mA Output
  • 15 pin D Sub and SMA sensor/input ports
  • “Set it & Forget It” Remote Data Logging
  • Power: USB or Built-in Re-Chargeable Battery Pack
  • Multi-System Simultaneous Continuous Monitoring
  • Includes DataLight II Software and Labview Sample Code
  • NIST-Traceable/ISO/IEC 17025:2017 Accredited Calibration
  • Sample Rate Up to 100 Hz, Programmable
  • Made in the USA
  • Custom & OEM Inquiries Welcome

 

< Back to Germicidal & UV Disinfection System Table 

< Back to Optical Radiation Hazard System Table

Response Curve

Effective Germicidal Detector

Configured with a spectral response weighted to match the IES Luckiesh and DIN standards for germicidal effectiveness.

Measurement Range: 3.00e-9 to 2.50e-3 effective Watts/cm2
Germicidal Spectral Range: 235 – 307 nm, calibration wavelength at 270 nm
Dimensions: 68 mm x 42 mm diameter
Order part numbers: ILT5000*, SED240/ACT5/W (detector)
* Software Included / Tablet PC Sold Separately

Applications: This detector has a weighted response and is specifically designed to measure the germicidal effectiveness of low-intensity, broad spectrum UV sources in accordance with the requirements within the IES Luckiesh and DIN standards.


Actinic Optical Radiation Hazard Detector

Specially designed with proprietary filtration for easy and accurate optical radiation hazard measurements in the UV Actinic range.


Measurement Range: 3.00e-10 to 2.50e-3 eff W/cm2
UV Actinic Hazard Spectral Range: 180 – 400 nm
Order part numbers: ILT5000*, SED240/ACT5/W (detector)
* Software Included / Tablet PC Sold Separately

Applications: This detector has been fitted with our proprietary UV Actinic Hazard filter giving the detector the required spectral response for taking UV optical radiation hazard measurements. Calibrated for readout in effective Watts per square centimeter. This system combination is capable of meeting UV hazard measurement standards that require instrumentation that can measure 0.1 microWatts per squared centimeter or better.
 

SED Detector

 

 

 

 

 





Filters and input optics are removable and may be ordered separately from the detector assembly to allow filter and input optic swapping

 

Note: For simultaneous multi-sensor data logging, ILT also offers the ILT6000 Rack-Mount Radiometer System with the same specifications as the ILT5000 in a 2-10 unit, rack mountable housing
 

ILT6000 Rack Mount Radiometer System

 

 

 

 

 

 

 

 

 

 

 

For the latest meter specifications, data sheet, installation guide, tech notes and software, visit the ILT5000 page here.